Installer’s Instruction
Federal law requires that WINE--MATE split cooling systems be
installed by an EPA certified refrigeration technician.
WINE-MATE split system is shipped as components and is ready for use only
after a certified refrigeration technician has properly installed, charged and tested
the system. Proper installation is critical. Vinotemp can only warrant the quality of
the components. The installation and proper operation of the system must be
warranted by the installer. Installation of the system must be done in accordance
with all state and local building codes.
The condensing unit and evaporator unit are connected by a liquid line and an
insulated suction line that are supplied by the installer. These lines must be
properly sized for the distance between the two units. After the units and the lines
are installed, the system must be pressure tested. If no leaks are found,
evacuate and charge system with R134A. Refrigerant amount will vary
depending on the length of line set.
1. Condensing Unit
Place the condensing units WM150-650SCU in a properly ventilated
location. If it is not, heat exhausted by the condensing unit will build up
and the cooling system will not operate properly.
Condensing unit shall be elevated to avoid possible flooding and shaded
from direct sun. It shall not be exposed to temperatures higher than 110
°F or lower than 45 °F (optional low ambient kit for 20 °F).
Leave minimum 5 feet clearance for the exhaust side and leave minimum
1 foot clearance for the fresh air intake side.
2. Evaporator Unit
Page view 0
1 2 3 4 5 6 7

Summary of Contents

Page 1 - Installer’s Instruction

VINO-1500SSL VINO-2500SSL VINO-4500SSL VINO-6500SSL Installer’s Instruction Federal law requires that WINE--MATE split cooling systems be installed

Page 2 - °F ambient temperatures

- 1 -• The WM15-65SFCL evaporator units shall be installed for ceilin

Page 3

- 2 -VINO-2500SSL <= 50 FT 1/4" OD 3/8” OD 1/2” OD R134a/ 20

Page 4

- 3 -6. Valve Operation SPINDLE BACK POSITION SPINDLE FRONT P

Page 5

- 4 - Fig. 2.3 VINO1500-4500SSL Wiring Diagram (DIGITAL CONTROLLER)

Page 6

- 5 - Fig. 2.5 VINO6500SSL Electrical Wiring Diagram (DIGITAL CONTROLL

Page 7 - Unit not running

- 6 -9. Condensing Unit Troubleshooting Unit not running a. Incorre