Vinotemp 2500CD Service Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 27
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
- 3 -
1. Introduction
VINOTEMP assumes no responsibility for any repairs made on
products by anyone other than authorized service technician
This manual has been prepared to provide the information on installing,
servicing, troubleshooting and repairing procedures for the WINE-MATE
VINO1500HZD & 2500 HZD cooling units.
I. Goals and Objectives
The goal of this manual is to provide detailed information that will enable the
service personnel to properly install and repair the cooling unit, and troubleshoot
and diagnose malfunctions.
The objectives of this manual are that the service personnel will
Fully understand the proper safety precautions
Successfully install the cooling unit
Successfully troubleshoot and diagnose malfunctions
Successfully perform necessary repairs
Successfully return the cooling unit to proper operational status
II. R134a Refrigerant Service Information
This cooling unit uses R134a refrigerant. This refrigerant requires synthetic ester
oil in the compressor. This cooling system does not tolerate contamination from
any of the following:
Other refrigerants
Moisture
Petroleum-based lubricants
Silicone lubricants
Cleaning components
Rust inhibitors
Leak detection dyes
Any other types of additive
As a result, the following precautions shall be observed:
Use equipment dedicated to R134a sealed system only.
Use R134a refrigerant for back-flushing.
Page view 3