- 14 -
D. Fan Wires: black shrunk wire from the fan terminal connecting the black
wire from the controller compressor output; white shrunk wire from fan
terminal connecting the neutral line;
Figure 3-1B (5 button controller)
A. Live Line (115VAC/60Hz): red shrunk wire from the power line
B. Neutral Line: white shrunk wire from the power line;
C. Compressor Wires: black shrunk wire from the compressor terminal
connecting the orange wire from the controller compressor output;
white shrunk wire from the compressor terminal connecting the neutral
line;
D. Fan Wires: black shrunk wire from the fan terminal connecting the black
wire from the controller fan output; white shrunk wire from the fan
terminal connecting the neutral line;
2) Compressor
The compressor acts as a pump, forcing
refrigerant through the sealed system.
Figure 3-2