Vinotemp 2500CD Service Manual Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 27
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
- 17 -
electronic controller will turn on the compressor and fan motors. Once the
selected temperature is sensed, the controller will turn off the cooling unit.
A. Resistance
1. Unplug WINEMATE cooling unit or disconnect power.
2. Disconnect the connector with the red and white wires connected to the
input of the electronic controller.
3. Touch and hold one ohmmeter probe to one terminal on the electronic
controller, then touch and hold the other probe to the other terminal.
4. The ohmmeter shall show a reading of 825 ± 10%.
5. Reconnect the wire connector to the electronic controller.
B. Input Live Voltage
Figure 3-4A (3 button controller)
Figure 3-4B (5 button controller)
1. The WINEMATE unit needs to be plugged in.
2. Locate the red and white wires going to the electronic controller.
Page view 17